Laurel Digital Panel Meters, Counters & Remote Displays

Laurel Digital Panel Meters offer high speed and 5-digit accuracy, plus hardware options and programmable features to solve complex industrial measurement and control problems at minimum cost. Laurel programmable transmitters, digital panel meters, electronic counters, industrial timers, and large digit displays set the standard of the industry with technical features and performance.  

Contact ThermX Southwest for availability and technical support with your application.  1-800-284-3769.

Digital Panel Meter Functions

  • Thermocouples & RTDs
  • DC Volts, mV, µV
  • DC Amps & mA
  • True AC RMS Volts & mV
  • True AC RMS Amps & mA
  • Process Signals
  • Potentiometer Follower
  • Strain Gages
  • Load cells, 4- and 6-wire
  • Weight / scale meter
  • Custom curve linearization

NEW Laurel DIN Rail Transmitters by Input & Output

4-20 mA Transmitters

  • AC rms Voltage & Current
  • DC Voltage & Current
  • Load Cell & Microvolt Signals
  • Process & Strain Gauge
  • Temperature
Laurel DIN Rail 4-20mA Transmitters

MODBUS Transmitters

  • AC rms Voltage & Current
  • DC Voltage & Current
  • Load Cell & Microvolt Signals
  • Process & Strain Gauge
  • Temperature
Laurel DIN Rail Transmitters

Programmable Counter Functions

  • Frequency, Rate, Period
  • Time Interval, Stopwatch
  • Phase Angle, Duty Cycle
  • Voltage-to-Frequency Converter:
    Analog Square Root, Analog Integrating Totalizer, Analog Batch Controller
  • Up / down Totalizer: with Square Root
    & Custom Curve Linearization
  • Pulse Input Batch controller
  • A+B, A-B, A*B, A/B, A/B-1 Draw
  • Quadrature Position & Rate

Panel Meter & Counter Standard Features

  • Simple setup via pushbuttons or computer.
  • Multifunction, high-resolution instrument at single-function price.
  • High read rate (60 converstion per second) for fast control response and true peak value display.
  • Adaptive filter eliminates noise, yet responds rapidly to changes in signal level.
  • Auto-tare for zeroing in weighing appli- cations.
  • Isolated 5, 10 and 24 Vdc excitation eliminates need for external supply.
  • Wide-range 85-264 Vac input power for global use.
  • Designed to meet international safety standards.
  • 1/8 DIN case for easy replacement of existing meters.
  • Plug-in screw terminals for power and signal included.
  • Sealed to NEMA-4X (IP-65) when panel mounted for high-pressure washdown.

Panel Meters & Counter Options

  • Dual setpoint relays: 10 A electrome- chanical relays or opto-isolated solid state relays for control and alarm.
  • Analog output: 0-20 mA plus 10 Vdc, isolated, linearized and scaled to display.
  • Serial I/O: isolated RS-232 or multipoint RS-485.
  • BCD output: isolated, parallel, stored, 3-state.
  • Low voltage power: for 8-28 Vac or
    9-37 Vdc operation off battery power.

Remote Display Functions

  • 6 digit LED display, -999999 to +999999.
  • Accepts RS-232 or RS-485 input from panel meter, counter, or other external source.
  • Up to 31 units addressable on one serial data line.
  • Optional dual-relay control output tied to display.
  • Optional isolated 0-10 V or 4-20 mA transmitter output tied to display.
Laurel Panel Meters

LAUREATE™ Series Hardware Overview

Modular Hardware

The design of the Laureate™ Series is modular for maximum flexibility at minimum cost. The base configuration for a panel meter or counter consists of a main module (with computer and plug-in display boards), a power supply board, and a signal conditioner board. Optional plug-in boards include an isolated setpoint controller board, an isolated analog output board, and an isolated digital interface board.

Modular design and a choice of plug-in options allow the Laureate to be customized for a broad range of applications from simple monitoring to control and computer interface. There can be up to five plug-in boards in a fully-loaded Laureate.

 

Main Module

The main module (with computer and display boards) defines the Laureate series (DPM, weight meter, counter, or remote display), version (standard or extended), and LED display color (red or green). The number of digits is 5 for DPMs or 6 for counters, weight meters and remote displays. Digits are a full 14.2 mm (0.56") high.

Power Supply Boards

The same standard switching power supply board handles inputs of 85-264 Vac for worldwide AC use, plus 90-370 Vdc. An optional low voltage power supply board handles 8-28 Vac and 9-37 Vdc, allowing the meter to be powered by batteries. Isolated 5, 10 or 24 Vdc transducer excitation output is standard with either supply.

  • 85 to 264 Vac and 90 to 370 Vdc
  • 8 to 28 Vac and 9 to 27 Vdc

Signal Conditioner Boards

Four input boards available for DPMs:

  • DC (volts, amps, mV, mA, process such as 4-20 mA, strain, pot follower).
  • Temperature (J, K, T, E, N, R, S thermocouple, Pt 100 ohm RTD).
  • True RMS (AC volts, mV, amps, mA).
  • Load cell (load cells, scale meter, strain gauges, microvolts).

Three input boards are available for counters:

  • Dual-channel counter: AC frequency, period, rate, time interval, stopwatch, phase angle, duty cycle, square root, up/down total, ratio or draw, A+B, A-B, AxB, A/B, batch control, custom curves.
  • Voltage-to-Frequency: rate, rate and total, square root, integrating totalizer, batch control, 1/rate (time), custom curves.
  • Quadrature: position or rate from encoders with low-level differential or single ended logic level outputs.

Setpoint Controller Boards

Two isolated setpoint controller options are available to add control and alarm capability to DPMs, counters and remote displays:

  • Dual 10 A relays
  • Dual isolated open collector transistor outputs

Analog Output Board

An optional isolated analog output board is available to provide 0-10 Vdc and 4-20 mA outputs for DPMs, counters and remote displays. It is ideal to drive a chart recorder or for transmission to a control room. The two outputs are linearized and independently scaled to the display. In the pulse input batch controller, a 10A relays fill the socket of the analog output board.

  • 0-10 Vdc and 0-20 mA analog output

Digital Interface Boards

Optional isolated interface boards allow the Laureate to communicate with a computer or PLC. The two serial boards allow the Laureate to drive a remote display, or to serve as a remote display.

  • Isolated RS-232
  • Isolated RS-485
  • Isolated, parallel BCD output

Designed for Industrial Installation

All Laureates are housed in a compact and rugged 1/8 DIN case which fits in a standard 45 x 92 mm panel cutout and requires only 102 mm (4.0") behind the panel (plus connectors). In many applications, a Laureate can replace a larger, more expensive instrument. The Laureate case is sealed to NEMA-4X (IP-65) requirements from the front when panel mounted to allow high-pressure washdown.

Connectors Included

All power and signal connections are via UL / IEC / CSA rated screw-clamp terminals, which are standard. The RS-232 and RS-485 options are connected via an RJ-11 phone jack. The BCD option uses a 30-pin, 0.1" mass termination ribbon cable connector.